Effect of TX-100 pretreatment on carbon paste electrode for selective sensing of dopamine in presence of paracetamol | Scientific Reports

2022-12-17 13:31:57 By : Ms. Judy Tian

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles and JavaScript.

Carousel with three slides shown at a time. Use the Previous and Next buttons to navigate three slides at a time, or the slide dot buttons at the end to jump three slides at a time. Methyl Trimethoxysilane

Effect of TX-100 pretreatment on carbon paste electrode for selective sensing of dopamine in presence of paracetamol | Scientific Reports

JK Shashikumara, BE Kumara Swamy, … Kaustubha Mohanty

K. Chetankumar, BE Kumara Swamy, … SA Hariprasad

Murugan Keerthi, Gopal Boopathy, … Bih-Show Lou

SD Sukanya, BE Kumara Swamy, … SA Hariprasad

Rajasekhar Chokkareddy, Suvardhan Kanchi & Inamuddin

Mohsen Keyvanfard, Hassan Karimi-Maleh, … Fatih Sen

Gilbert Ringgit, Shafiquzzaman Siddiquee, … Mohammad Tamrin Mohamad Lal

Žaklina Z. Tasić, Marija B. Petrović Mihajlović, ... Milan M. Antonijević

K. Chetankumar, BE Kumara Swamy, … H. Adarsha

Scientific Reports volume  12, Article number: 20292 (2022 ) Cite this article

Dopamine (DA) is one of the chief neurotransmitters present in the central nervous system of mammals. Therefore detection of DA in presence of various analytes like paracetamol has great importance. In the current work, we are proposing that Triton X-100 (TX-100) pretreated carbon paste electrode (CPE) can be useful to detect the DA selectively in presence of PA. After the pretreatment CPE can detect DA in presence of PA effectively. Cyclic voltammetry was employed to observe the amplified electron transfer reaction between the modified CPE and DA. To understand electron transfer regioselectivity at the TX-100 pretreated CPE, a dual descriptor was used. The prepared electrode showed satisfactory stability when kept under ambient conditions. The proposed approach also showed excellent analytical applicability to identify DA and PA in commercial formulations. The scope of the work is limited to detecting DA in presence of PA. We will consider the other interferes for future works.

Now-day researchers are more concentrating on carbon paste electrodes (CPEs) to utilize them as working electrodes in electrochemical sensors applications. CPEs offer several appealing properties, including surface repeatability, stability, and renewability, making them appealing substances for working electrodes1,2,3. Due to their inexpensive cost relative to other materials, CPEs are becoming more widely used in areas such as pharmaceutical, biological, and environmental analysis4,5.

Physical or chemical modifications can improve CPE's sensing properties like selectivity, adsorption capacity, and sensitivity6,7. The goal of modifying a CPE matrix is to create an efficient electrode with sensing properties that will be useful for users. In general, after modifications, electrocatalytic activities at the CPE interface will improve, which may be due to the increased surface area which in turn gives better current sensitivity for electron transfer reactions. CPE can be chemically modified using conductive substrates modified with electroactive thin films, monolayers, or thick coatings8,9.

The electrochemical modifications may include the use of different types of surfactants to modify the CPE. Clay minerals treated with surfactants have excellent sorption capabilities for both organic and inorganic substances in aqueous solutions10,11. In terms of electrode modification, T-octylphenoxypolyethoxyethanol (Triton X-100 (TX100)) is one of the best nonionic surfactants12,13,14,15,16. The properties of hybrid materials (carbon paste + TX-100) are highly promising. TX-100 modified carbon hybrid materials are previously reported to use as electrodes. TX-100 adsorbed electrode alters the electrode–electrolyte interface, making it easier to create poly (m-toluidine) films with higher current densities16. TX-100 modified CPE was prepared by surface immobilization technique by B.N. Chandrashekar et al. and this method exhibit good sensitivity, but TX-100 pretreatment is more applicable than this method17. According to the literature, modification of electrodes using TX-100 has several works but the pre-treatment method good one for analysis of biomolecules proved by the present work18,19.

The modifications of electrodes can be done by methods like mechanical grinding, self-assembled layers, covalently bonded electrolyzers, surfactant immobilization, etc. The electrochemical pre-treatment process increases the electron transfer compared to others. To use carbon surface effectively one must take care of the degree of activation20. The modification of CPEs is achieved simply by pre-treatment of TX-100 modifier with the carbon paste which is enhancing the sensitivity and selectivity of the electrochemical analysis technique.

Because of its simplicity, sensitivity, efficiency, and low cost, electrochemical pretreatment was chosen for this study. Pretreatment is considered environmentally benign since it uses less dangerous chemicals than other time-consuming and sophisticated modification materials. The electrochemical pretreatment procedure results in transducers that produce signals that are undistorted, well-defined, and repeatable. By creating charge-carrying functional groups, the pretreatment of the CPE enhances the selectivity and sensitivity of the sensors for detecting selected electroactive components. In the present work, we study the effect of TX-100 pretreatment on CPE, and it is used in applications for DA and PA sensors with performing the detection of DA in the presence of PA because the usage of PA protects dopaminergic neurons against oxidative stress damage produced by acute exposure to increased amounts of DA, according to in vitro studies21 and it shows outstanding stability, sensitivity, and selectivity for biomedical applications.

Paracetamol (PA) was obtained from Merck, sodium hydroxide (NaOH), and dopamine hydrochlorides (DA) from nice chemicals. The graphite powder (LobaChemie), Silicone oil and TX-100 are obtained from Himedia.

The TX-100 atomic model has created with Sinapsis software (Version: Sinapsis.XIII Weblink: http://sinapsis.sourceforge.net Acess date: accessed July 20, 2020)22. The experiments were done using the potentiostat model CHI-660c (CH Instrument-660 electrochemical workstation) and the generated data was transferred to origin 6.1. Bare CPE (BCPE), NaOH pretreated modified CPE (NaOH-PT-MCPE), and TX-100 pretreated modified CPE (TX-100PT-MCPE) are used as working electrodes, saturated calomel as the reference electrode, and a platinum electrode as a counter electrode.

The BCPE was prepared by hand mixing 70% graphite powder with 30% silicon oil in an agate mortar for approximately 30 min to produce a homogenous carbon paste. The paste was packed into the homemade cavity of a Teflon tube and polished on a paper napkin to obtain a uniform surface.

The pretreatment process was carried out using cyclic voltammetry (CV), potential cycles were between − 0.4 and 0.9 V at a scan rate (ν) of 1 V/s for 100 cycles as depicted in Fig. 1A. With an increase in the cycle number voltammogram, currents decreased gradually which indicates that during the pretreatment process TX-100 is adsorbing on the electrode surface. To eliminate contaminants electrode was dipped in deionized water. The electrochemical response of TX-100PT-MCPE with different cycles is measured by using potassium ferrocyanide, K4(Fe (CN)6) at a sweep rate of 50 mV/s is depicted in Fig. 1B. TX-100PT-MCPE prepared by 100 cycles showed better sensing capability hence it is considered for further analysis.

(A) CVs for electrodeposition of TX-100 on a BCPE in 0.1 M NaOH by 100 cycles. Sweep rate: 1 Vs−1. (B)The graph of anodic peak current versus several cycles for potassium ferrocyanide at a sweep rate of 50 mV/s.

The TX-100 atomic model was created with Sinapsis software22 as shown in Fig. 2 and geometry optimization was done with deMon2k software23 using PBE exchange - correlation functions24,25 and TZVP basis sets26, employing density functional theory (DFT) as described in our previous articles. Sinapsis software was used to plot the dual descriptor results.

Atomistic model of Triton X-100 (H = white, C = grey, and O = red).

The cyclic voltammetric (CV) response of K4(Fe(CN)6 at TX-100-PTCPE is shown in Fig. 3A. The BCPEs had poor peak current and high redox peak potential differences, but the MCPEs had much-improved redox peak current signals and smaller redox peak potential discrepancies. Randle’s Sevick's equation27 was used to calculate the total active surface area. The active surface area for electrodes (BCPE, NaOH-PT-MCPE, and TX-100PT-MCPE) is shown in Table 1.

(A) CVs of 1 mM potassium ferrocyanide in 1 M KCl solution at a speed rate of 50 mV/s. (B) Dual descriptor result of TX-100 [ISO = 0.07, grid = 0.3].

The heterogeneous rate constant (k0) values for K4(Fe (CN)6 are calculated from the ΔEp values (> 10 mV) using Eq. (1). The k0 values are listed in Table 2.

TX-100 redox sites are found using ADPT-based dual descriptor calculations. The dual descriptors or dual Fukui functions are obtained using Fukui functions. Fukui functions can be defined according to Eq. (2)26. Previously we have used the Fukui functions to analyze surfactants28,29.

where N is the number of electrons in the system, ρ(r) is the electron density, + and − signs correspond to the addition or remotion of electrons, respectively. The dual descriptor (\({f}_{D}\) ) is plotted using Eq. (3).

The dual descriptor charts for TX-100 are shown in Fig. 3B22. The blue colour regions in our dual descriptor maps indicate TX-100 oxidation sites, whereas the red colour regions represent TX-100 reduction sites. TX-100 is oxidized via the tail due to the presence of oxygen atoms with lone pair electrons, and it is reduced via the head phenyl ring.

The voltammetric response of DA (10 µM) at the BCPE, NaOH-PTMCPE, and TX-100PT-MCPE was displayed in Fig. 4. The peak potential difference (ΔEp) was 58 mV at BCPE. However, ΔEp values are 28 mV and 25 mV for NaOH-PT-MCPE and TX-100-PTMCPE respectively. This indicates that pretreated electrodes are good for sensing applications.

CVs for 10 µM DA in 0.2 M PBS solution of pH 7.4 at pretreated NaOH and TX-100-PT-MCPE at the sweep rate of 100 mV/s. Inset: compares the BCPE and NaOH pretreatment.

As shown in Fig. 5A, the effect of change in the ν for 10 µM DA in 0.2 M PBS was studied by CV at TX-100PT-MCPE. The TX-100PT-MCPE demonstrates that as the ν increases the redox peak current steadily increases. The plot of anodic peak current (Ipa) vs ν verifies the type of electrode process (Inset of Fig. 5B). The correlation coefficient was originally set at R2 = 0.9997, however, Fig. 5C depicts a plot of log Ipa vs log ν with 0.8362 slopes. Therefore, the mass transfer process is adsorption controlled30.

(A) CVs of 10 µM DA in 0.2 M PBS solution of pH 7.4 at TX-100-PT-MCPE at different sweep rates. (a–j; 20–200 mV/s). (B) Graph of peak current versus sweep rate. (C) Graph of the log of peak current versus the log of sweep rate.

Figure 6A displays the CV response of DA at TX-100-PT-MCPE at different concentrations of 10–60 μM using 0.2 M PBS (pH 7.4) with a ν 100 mV/s. With a rise in concentration, the corresponding anodic peak current (Ipa) of DA enhances. Figure 6B shows the curve of Ipa vs DA concentration. It has high linearity with regression equations are Ipa(μA) = 42 (μM) + 0.105 (R2 = 0.9981) and the limit of detection (LOD) and limit of quantification (LOQ) are calculated according to Eqs. (4, 5)30. Where S is the standard deviation and M is the slope obtained from the calibration plot:

(A) CVs of 10 µM DA in 0.2 M PBS solution of pH 7.4 at TX-100-PT-MCPE at a sweep rate of 50 mV/s with different concentrations (a–f: 10–60 μM). (B) Graph of anodic peak current versus concentration of DA.

The comparative analytical performance electrode for DA was presented in Table 331,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47 and LOQ was found to be 4.08 μM.

The CVs for DA obtained by the TX-100-PT-MCPE at ν of 100 mV/s in PBS of various pH from 6.2 to 7.8 for DA are shown in Fig. 7A. The Ipa of DA changed to a less positive potential as the pH increased. A graph of Epa vs different pH levels was used to create the potential diagram (Fig. 7B). With a slope of 55 mV/pH, the obtained graphs exhibit acceptable linearity with regression equations are EpDA (mV) =  − 55 pH + 56 (R2 = 0.9989). The calculated slope is extremely near to the Nernstian value of 59 mV, as shown in the graphs. Therefore, an equal number of protons and electrons are transferred in the reactions (Fig. 7C).

(A) CVs of 10 µM DA for different pH (6.2–7.8 pH) at TX-100-PT-MCPE. (B) Graph of Epa versus different pH. (C) Redox mechanism dopamine.

A CV profile of 10 μM PA at BCPE and TX-100PT-MCPE in 0.2 M PBS is shown in Fig. 8 (pH 7.4). The TX-100PT-MCPE shows an increase in redox Ipa and a small shift in potential, but the BCPE, PA shows less current and more widespread peaks. Our findings show that following the change, the electrode performs well and lowers ΔE while increasing Ipa. These findings show that the proposed sensor has a catalytic effect on PA analysis.

CVs of 10 µM PA in 0.2 M PBS solution of pH 7.4 at BCPE and TX-100-PT-MCPE at the sweep rate of 100 mV/s.

At TX-100-PT-MCPE, the effect of ν on the CV performance of the PA was investigated in PBS (pH 7.4). Ipa increased with a slight positive shift in the peak potential displayed in Fig. 9A increased in the region of 20–200 mV/s. In Fig. 9B,C, the current intensity changes in terms of sweep rates are shown in a graph with good linearity. The findings show that the oxidation–reduction process of PA is influenced by adsorption.

(A) Cyclic voltammograms of 10 µM PA in 0.2 M PBS solution of pH 7.4 at TX-100-PT-MCPE at different sweep rates. (a–j; 20–200 mV/s). (B) Graph of peak current versus sweep rate. (C) Graph of the log of peak current versus the log of sweep rate.

PA CVs at TX-100-PT-MCPE at various concentrations are depicted in Fig. 10A. PA's Ipa hikes with an increase in concentration shown in Fig. 10B. The linearity of the Ipa vs. PA concentration was found high linearity with regression equations are Ipa(μA) = 01 (μM) + 0.15 (R2 = 0.99979) and the limit of detection (LOD) and limit of quantification (LOQ) are calculated according to Eqs. (4, 5) and are found to be 5.031 μM and 16.77 μM respectively.

(A) CVs of 10 µM PA in 0.2 M PBS solution of pH 7.4 at TX-100-PT-MCPE at a sweep rate of 50 mV/s with different concentrations (a–f: 10–60 μM). (B) Graph of anodic peak current versus concentration of PA.

The CVs profile for PA, at TX-100-PT-MCPE in 0.2 M PBS range 6.2–7.8 is portrayed in Fig. 11A. The Epa was moved negative with an increase in pH values. Figure 11B portrayed the linear establishment between Epa and pH and provide a slope of 57 mV for PA with regression equations are EpDA (mV) =  − 57 pH + 58 (R2 = 0.9997). The resulting slope is close to the Nernstian value. Therefore, an equal number of protons and electrons are transferred in the reactions (Fig. 11C).

(A) Cyclic voltammograms of 10 µM PA for different pH (from a–e; 6.2–7.8 pH) at pretreated TX-100 modified CPE. (B) Graph of Epa versus different pH. (C) Redox mechanism paracetamol.

Figure 12A displays the CV responses of 10 µM of DA and 10 µM PA in 0.2 M PBS of both BCPE and TX-100PT-MCPE. The BCPE showed short current signals with poor selectivity indicating that electrode is not selective for simultaneous detection of DA and PA. But after TX-100 pretreatment current signals are enhanced and selectivity was improved (oxidation potential of DA and PA are separated). Therefore, TX-100PT-MCPE can effectively be used to detect DA in presence of PA. The fabrication reproducibility was checked by successively scanning 50 cycle’s depicted in Fig. 12B. The Ip signals retained approximately 90.6% of the original value. The experimental results indicated that the TX-100PT-MCPE possesses a long service life.

(A) CVs for simultaneous determination for 10 µM DA and 10 µM PA at BCPE (dashed line) and TX-100-PT-MCPE (solid line) at a sweep rate of 100 mV/s. (B) CVs of 1 mM potassium ferrocyanide in 1 M KCl solution at a speed rate of 50 mV/s for stability analysis for TX-100-PT-MCPE at 50 cycles.

Figure 13A displays the DPVs of DA at 5–40 µM concentration in presence of 5 µM PA. As a result, the Ipa of DA increases with an increase in DA concentration, and the Ipa of PA remains constant. The obtained results are good as shown in the graph of Ipa versus the concentration of DA (Fig. 13B). This indicates that TX-100-PT-MCPE can selectively sense DA in presence of PA.

(A) Differential pulse voltammograms were obtained for variation of concentration 5–40 µM (a–h) DA, in PBS (pH 7.4), in the presence of 5 µM PA at TX-100-PT-MCPE. (B) Graph of anodic peak current versus concentration of DA.

Figure 14A demonstrates raising the concentration of PA from 5 to 40 µM while maintaining the DA concentration constant (5 µM). The curve of Ipa vs concentration of PA is depicted in Fig. 14B and it is linear. The result confirms that changing the concentration of one analyte does not affect the peak current and peak potential of another analyte; it also demonstrates the modified carbon paste electrode's outstanding selectivity and sensitivity towards DA and PA.

(A) Differential pulse voltammograms obtained for variation of concentration 5–40 µM (a–h) PA, in PBS (pH 7.4), in the presence of 5 µM DA at pretreated TX-100 modified CPE. (B) Graph of anodic peak current versus concentration of PA.

For the examination of DA-containing injectable samples and PA tablet samples by standard addition method using TX-100PT-MCPE. The injection samples and DA injection were utilized after a sufficient dilution with a 0.2 M phosphate buffer. Dolo-500, Micro Labs Ltd provided the PA tablet sample, which had a PA 500 mg concentration. The obtained results are tabulated in Table 4. The recovery was acceptable, indicating that the proposed methods may be utilized to detect DA in injections with a recovery rate of 98.20–99.10 percent and a recovery rate of 98.5–99.45 percent for the PA tablet sample.

The pretreatment of the CPE with TX-100 in 0.1 M NaOH solution results in a very stable DA sensor with outstanding sensitivity and selectivity. The TX-100PT-MCPE reduced the overpotential and enhanced the current responsiveness. The pH study reveals that the redox mechanism involves an equal quantity of protons and electrons being transferred. This demonstrated a promising biological use. The prepared electrode showed satisfactory stability when kept under ambient conditions. The proposed approach is also used to identify DA in injectable samples and PA in commercial tablet formulations.

Abdel Rahim, A. M. & Abdel Gaber, A. A. Fabrication and characterization of extrinsic electrochemically modified graphite reinforcement carbon paste electrode for selective determination of Cu(II) in trace levels. Appl. Surf. Sci. Adv. 2, 100031 (2020).

Cariati, L. S. S. & Buoro, R. M. Evaluation of ionic natural deep eutectic solvents (NADES) modified binders towards the chemical properties of carbon paste electrodes. Electrochem. Commun. 109, 106605 (2019).

Walid, B. et al. Elaboration of carbon paste electrode containing pentadentate Nickel-(II) Schiff base complex: Application to electrochemical oxidation of thiosulfate in alkaline medium. Arab. J. Chem. 13(7), 6072–6083 (2020).

Olga, V. et al. Use of carbon paste electrode and modified by gold nanoparticles for selected macrolide antibiotics determination as standard and in pharmaceutical preparations. J. Electroanal. Chem. 873, 114324 (2020).

Mehdi, R.-N. et al. A modified sensitive carbon paste electrode for 5-fluorouracil based using a composite of praseodymium erbium tungstate. Microchem. J. 154, 104654 (2020).

Piovesan, J. V., Santana, E. R. & Almir, S. A carbon paste electrode improved with poly (ethylene glycol) for tannic acid surveillance in beer samples. Food Chem. 326, 127055 (2020).

Article  CAS  PubMed  Google Scholar 

Saleh, A. T., Khaled, M. M. & Abdur, R. Electrochemical sensor for the determination of ketoconazole based on gold nanoparticles modified carbon paste electrode. J. Mol. Liq. 256, 39–48 (2018).

Janata, J. & Josowicz, M. Conducting polymers in electronic chemical sensors. Nat. Mater. 2, 19–24 (2003).

Article  ADS  CAS  PubMed  Google Scholar 

Cristina, S. et al. Sensitive voltammetry determination of riboflavin in pharmaceutical and biological samples using FSN-Zonyl-Nafion modified carbon paste electrode. Microchem. J. 155, 104729 (2020).

Lili, Z., Yuhua, C. & Guangqun, C. Electrochemical sensor based on magnetic molecularly imprinted nanoparticles at surfactant modified magnetic electrode for determination of bisphenol A. Biosens. Bioelectron. 54, 258–261 (2014).

Thomas, T. et al. Pristine multi-walled carbon nanotubes/SDS modified carbon paste electrode as an amperometric sensor for epinephrine. Talanta 125, 352–360 (2014).

Article  CAS  PubMed  Google Scholar 

Lokhande, P. E., Pawar, K. & Chavan, U. S. Chemically deposited ultrathin α-Ni(OH)2 nanosheet using surfactant on Ni foam for high-performance supercapacitor application. Mater. Sci. Energy Technol. 1, 166–170 (2018).

Biaselle, C. J. & Millar, D. B. Studies on triton X-100 detergent micelles. Biophys. Chem. 3, 355 (1975).

Article  CAS  PubMed  Google Scholar 

Jayaprakash, G. K. & Flores-Moreno, R. Quantum chemical study of TX-100 modified graphene surface. Electrochim. Acta 248, 225–231 (2017).

Marzieh, M. & Shahla, E. Colorimetric detection of insulin in human serum using GO/AuNPs/TX-100 nanocomposite. Spectrochim. Acta Part A Mol. Biomol. Spectrosc. 240, 118617 (2020).

Jayaprakash, G. K., Kumara Swamy, B. E., Casillas, N. & Flores-Moreno, R. Analytical Fukui and cyclic voltammetric studies on ferrocene modified carbon electrodes and effect of TX-100 on it. Electrochim. Acta 258, 1025–1034 (2017).

Chandrashekara, B. N. & Kumara Swamy, B. E. Simultaneous cyclic voltammetric determination of norepinephrine, ascorbic acid and uric acid using TX-100 modified carbon paste electrode: A cyclic voltammetric study. Anal. Methods 4, 849 (2012).

Fang, J., Xie, Z., Wallace, G. & Wang, X. Co-deposition of carbon dots and reduced graphene oxide nanosheets on carbon-fiber microelectrode surface for selective detection of dopamine. Appl. Surf. Sci. 412, 131–137 (2017).

Article  ADS  CAS  Google Scholar 

Andrea, P., Rojas, S., Cortes, M. & Hurtado, J. Electrochemical synthesis of poly (3,4-ethylene dioxythiophene) doped with a new bis(pyrazolyl)methane disulfonate and its behaviour towards dopamine detection. J. Electroanal. Chem. 837, 200–207 (2019).

Rana, A., Baig, N. & Saleh, T. A. Electrochemically pretreated carbon electrodes and their electroanalytical applications—a review. J. Electroanal. Chem. 833, 313–332 (2019).

Sukanya Swamy, B. E. K., Shashikumara, J. K., Sharma, S. C. & Hariprasad, S. A. Poly (Orange CD) sensor for paracetamol in presence of folic acid and dopamine. Sci. Rep. 11, 22332 (2021).

Article  ADS  PubMed  Google Scholar 

Flores-Moreno , R. , Urbina , KP & Sandoval , ZG Synapse , Versions XII-V .Synapsis Developers, 2012. (Version: Synapsis. XIII Weblink: http://synapsis.sourceforge.net. Accessed 20 July

Gerald, G. et al. demon2k. Wiley Interdiscip. Rev. Comput. Mol. Sci. 2, 548–555 (2012).

Perdew, J. P. et al. Generalized gradient approximation made simple. Phys. Rev. Lett. 77, 3865–3868 (1996).

Article  ADS  CAS  PubMed  Google Scholar 

Perdew, J. P. et al. Generalized gradient approximation made simple. Phys. Rev. Lett. 78, 1396–1396 (1997).

Article  ADS  CAS  Google Scholar 

Godbout, N. et al. Optimization of Gaussian-type basis sets for local spin density functional calculations. Part I. Boron through neon, optimization technique and validation. Can. J. Chem. 70, 560–571 (1992).

Parr, R. G. & Yang, W. Density functional approach to the frontier–electron theory of chemical reactivity. J. Am. Chem. Soc. 106, 4049–4050 (1984).

Jayaprakash, G. K. et al. Dual descriptor analysis of cetylpyridinium modified carbon paste electrodes for ascorbic acid sensing applications. J. Mol. Liquids 334, 116348/1–17 (2021).

Jayaprakash, G. K. et al. Electrochemical and quantum chemical studies of cetylpyridinium bromide modified carbon electrode interface for sensor applications. J. Mol. Liq. 315(113719), 1–10 (2020).

Shashikumara, J. K. et al. Effect of RGO-Y2O3 and RGO-Y2O3:Cr3+ nanocomposite sensor for dopamine. Sci. Rep. 11, 9372/1–11 (2021).

Pruneanu, S. et al. The influence of uric and ascorbic acid on the electrochemical detection of dopamine using graphene-modified electrodes. Electrochim. Acta 154, 197 (2015).

Thiagarajan, S. & Chen, S. M. Preparation and characterization of Pt Au hybrid film modified electrodes and their use in the simultaneous determination of dopamine, ascorbic acid and uric acid. Talanta 74(2), 212–222 (2007).

Article  CAS  PubMed  Google Scholar 

Corona-Avendano, S. et al. Influence of CTAB on the electrochemical behaviour of dopamine and its analytic determination in the presence of ascorbic acid. J. Appl. Electrochem. 40, 463 (2010).

Ali Kamyabi, M. & Aghajanloo, F. Electrocatalytic response of dopamine at a CPE modified with ferrocene. Roat Che Act 82, 599–606 (2009).

Sunil Kumar Naik, T. S., Muthui Martin, M. & Kumara Swamy, B. E. Fabrication of poly (Sudan III) modified carbon paste electrode sensor for dopamine: A voltammetric study. J. Electroanal. Chem. 834, 73 (2018).

Goyal, R. N. & Singh, S. P. Simultaneous voltammetric determination of dopamine and adenosine using a single-walled carbon nanotube—MCPE. Carbon 46, 1556–1562 (2008).

Wang, Q., Li, N. & Wang, W. Electrocatalytic response of dopamine at a metallothioneins self-assembled gold electrode. Anal. Sci. 18, 635 (2002).

Article  CAS  PubMed  Google Scholar 

Zhu, Z. et al. Electrochemical detection of dopamine on a Ni/Al layered double hydroxide modified carbon ionic liquid electrode. Sens. Actuators B 151, 146–152 (2010).

Kaur, B., Pandiyan, T., Satpati, B. & Srivastava, R. Simultaneous and sensitive determination of ascorbic acid, dopamine, uric acid, and tryptophan with silver nanoparticles-decorated reduced graphene oxide modified electrode. Colloids Surf. B 111, 97–106 (2013).

Silva, L. V. D. et al. Amperometric sensor based on carbon nanotubes and electropolymerized vanillic acid for simultaneous determination of ascorbic acid, dopamine, and uric acid. J. Solid State Electrochem. 20, 2389–2393 (2016).

Chih, Y. K. & Yang, M. C. Simultaneous detection of dopamine and ascorbic acid using silver. Taiwan Inst. Chem. Eng. 45, 833–839 (2014).

Liu, R. et al. A glassy carbon electrode modified with an amphiphilic, electroactive and photosensitive polymer and with multi-walled carbon nanotubes for simultaneous determination of dopamine and paracetamol. Microchim. Acta 183, 1543–1551 (2016).

Shashikumara, J. K., KumaraSwamy, B. E. & Madhuchandra, H. D. Poly (amido black) modified carbon paste electrode sensor for dopamine in the presence of uric acid. Mater. Sci. Energy Technol. 3, 390–396 (2020).

Yang, Y. J. & Li, W. K. CTAB functionalized graphene oxide/multiwalled carbon nanotube composite modified electrode for the simultaneous determination of ascorbic acid, dopamine, uric acid and nitrite. Sens. Actuators B Chem. 56, 300–306 (2014).

de Matos Morawski, F. et al. A novel electrochemical platform based on mesoporous silica/titania and gold nanoparticles for simultaneous determination of norepinephrine and dopamine. Mater. Sci. Eng. C 120, 111646 (2021).

Roduan, M. R. A. M. et al. New modified mesoporous silica nanoparticles with bimetallic Ni-Zr for electroanalytical detection of dopamine. J. Electrochem. Sci. Eng. 12, 463–474 (2022).

Ahmed, J., Faisal, M., Harraz, F. A., Jalalah, M. & Alsareii, S. A. Development of an amperometric biosensor for dopamine using novel mesoporous silicon nanoparticles fabricated via a facile stain etching approach. Phys. E 135, 114952 (2022).

This article was funded by Jain University.

Department of PG Studies and Research in Industrial Chemistry, JnanaSahyadri, Kuvempu University, Shankaraghatta, Shivamogga, Karnataka, 577451, India

J. K. Shashi Kumara & B. E. Kumara Swamy

Department of Chemistry, Nitte Meenakshi Institute of Technology, Bangalore, Karnataka, 560064, India

National Assessment and Accreditation Council (Work Carried Out As Honorary Professor), Jain University, Bangalore, Karnataka, 560 069, India

School of Energy Science and Engineering, Indian Institute of Technology Guwahati, Guwahati, 781039, India

Department of Chemistry, University Center for Exact Sciences and Engineering, Universidad Guadalajara, Blvd. Marcelino Garcı´a Barraga´N 1421, CP 44430, Guadalajara, Jal., Mexico

Department of Chemical Engineering, Indian lnstitute of Technology Guwahati, Guwahati, 781039, India

Jain University, Bangalore, Karnataka, 560 069, India

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

You can also search for this author in PubMed  Google Scholar

J.K.S.K: electrochemical sensors experiments, formal analysis, writing—original draft. B.E.K.S.: conceptualization, supervision, writing—review and editing. G.K.J.: theoretical work, writing—review. S.C.S.: writing—review and editing. R.F.-M.: theoretical work, writing—review. K.M.: writing—review. S.A.H.: writing—review and editing.

Correspondence to B. E. Kumara Swamy or S. C. Sharma.

The authors declare no competing interests.

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Kumara, J.K.S., Swamy, B.E.K., Jayaprakash, G.K. et al. Effect of TX-100 pretreatment on carbon paste electrode for selective sensing of dopamine in presence of paracetamol. Sci Rep 12, 20292 (2022). https://doi.org/10.1038/s41598-022-24387-z

DOI: https://doi.org/10.1038/s41598-022-24387-z

Anyone you share the following link with will be able to read this content:

Sorry, a shareable link is not currently available for this article.

Provided by the Springer Nature SharedIt content-sharing initiative

By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.

Scientific Reports (Sci Rep) ISSN 2045-2322 (online)

Effect of TX-100 pretreatment on carbon paste electrode for selective sensing of dopamine in presence of paracetamol | Scientific Reports

Vinyl Silicone Oil Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.